Eizo Radiforce GX560 21.3" 5MP Monochrome LCD Monitor

Stock Code:
GX560-MD
Stock Code:
GX560
POA
POA

Add To Cart

Description

Eizo Radiforce GX560 21.3" 3MP Monochrome LCD Monitor


Distraction-Free Viewing
With a 7.5 mm bezel, the world's narrowest bezel on a 5 megapixel monitor, the total distance between two side-by-side screens is only 15 mm. Furthermore the screen is almost completely flat with the bezel sitting only 2.5 mm above the screen.

Space Saving
Due to the thinner bezels, the GX560 MammoDuo is slimmer than two conventional 5 megapixel monitors by 67 mm horizontally, 36 mm vertically and 20.5 mm in depth. Furthermore, the total occupying space is reduced by 22%.

Easy Adjustment
With the newly designed stand, you can adjust the height, tilt, and swivel of the two monitors without any gaps appearing between them.

Evolve Your Image Reading
As more image modalities become digitalized, radiologists are viewing an increasing amount of information on their screens. EIZO's unique Work-and-Flow technology alleviates the complexity of the imaging workflow with new functions developed with the radiologist in mind. Users can take advantage of Work-and-Flow functions with the RadiForce monitor and bundled RadiCS LE software.

Barrier-Free Workstyle
With the Switch-and-Go function, you can operate two different workstations at the same time with a single mouse and keyboard. Work across several monitors by moving the cursor from one screen to the other or switch the signals between workstations as needed without having to change your mouse or keyboard each time. This makes it possible to reduce the number of monitors in the workflow and improves work efficiency.

Quick and Easy Focus
With the Point-and-Focus function, you can quickly select and focus areas of your concern with just your mouse and keyboard. Change the brightness and grayscale tones of certain points on the screen to make interpretation easier.

View Mammography Images Clearly
5 megapixel monitors allow you to see smaller details that are essential in digital mammography. The high resolution retains important information to prevent decreased image quality and pixelation that occurs when viewing at a lower resolution.

Optimum Breast Screening Monitor
The GX560 adopts an LTPS (Low Temperature Polysilicon) panel, which allows the monitor to achieve a maximum brightness of 2,500 cd/m2. If calibrated to the recommended brightness of 1000 cd/m2, EIZO guarantees 5 years of use.

Furthermore, it has a contrast ratio of 1700:1, displaying deep blacks and bright whites without any washout. This makes it suitable to use with breast tomosynthesis and mammography which require clear visibility.

The monitor has obtained FDA 510(k) clearance by the U.S. Food and Drug Administration for breast tomosynthesis and mammography. This ensures that the monitor is capable of displaying detailed breast screening images where high performance is essential.

High Definition Display with Smooth Transition
The monitor has a response time of 12 milliseconds, making it ideal for smoothly and continuously viewing tomographic images such as breast tomosynthesis, MRI and CT. In addition, with a pixel pitch of 0.165 mm and 10-bit (1,024 tones) simultaneous grayscale display, subtle density differences can be easily distinguished.

Achieve Clarity True to the Source Data
A medical monitor needs to be capable of high brightness in order to meet performance standards. However, in order to achieve high brightness in an LCD panel, the pixel aperture ratio has to be increased. This causes a typically unavoidable decline in sharpness. With EIZO's unique Sharpness Recovery technology, the decrease in sharpness (MTF) is restored. This allows you to display an image safely on the monitor that is true to the original source data, even at high brightness levels.

MTF measures numerically how faithfully the panel transfers detail from the original image data for viewing. When Sharpness Recovery is turned on, in the case of a 2 pixel line pair (spatial frequency of 1.515 cycles/mm) the MTF increases by approximately 45.5%.

Variations for Specific User Needs
EIZO offers anti-glare (AG) and anti-reflection (AR) screen variations to suit user environments. AG treatment is ideal for exceptionally bright environments and drastically reduces glare from ambient lighting. AR treatment is ideal for moderately-lit environments to reduce mild screen glare while maintaining crisp text and images.

Hassle-Free Multi-Monitor Configuration
Using the DisplayPort connection, you can drive several monitors in a daisy chain sequence. This allows you to configure a multi-monitor setup without the complicated hassle of excessive cabling.

Make the Precise Diagnosis
EIZO carefully measures and sets each grayscale tone to create a monitor compliant with DICOM Part 14. Furthermore, at startup or upon wakeup, the EIZO patented drift correction function quickly stabilizes the brightness level and compensates the brightness fluctuations caused by the ambient temperature and the passage of time, allowing medical images to be faithfully reproduced with stable brightness and grayscale.

Manage Effortless Quality Control
With the RadiCS LE software (included) and Integrated Front Sensor (IFS) built into the front bezel, you can easily calibrate to DICOM Part 14 without having to mount, run, and remove an external sensor.

Simple calibration using the monitor backlight sensor is also supported.

Select the Ideal Mode for Modalities
The CAL Switch function allows you to choose various modes for different modalities such as mammography, MRI, and endoscopy. It can be conveniently accessed using the monitor's front panel buttons to easily switch to optimal image viewing conditions.

Conserve Energy While Away
A presence sensor prompts the monitor to switch to power save mode when the user is away and resumes operation upon their return to conserve power when not in use, uniting convenience with savings.

Digital Mammography Monitor Quality Control Standards Compliance
EIZO's easy-to-use RadiCS UX2 quality control software & calibration sensor (sold separately) performs precise calibration conforming to DICOM Part 14 and enables quality control complying with ACR Practice Guideline and other QC standard for digital mammography monitors.

Rest Assured with Medical Qualifications
The monitor meets the strictest medical, safety, and EMC emission standards.

Warranty with Safety and Trust
Click here for Warranty Information

Eizo Radiforce GX560 21.3" 3MP Monochrome LCD Monitor


Model Variations
GX560-BK-MD: Anti-Glare coating, two screens, with dual stand, black
GX560-ARBK-MD: Anti-Reflection coating, two screens, with dual stand, black
GX560-BK: Anti-Glare coating, one screen, with stand, black
GX560-ARBK: Anti-Reflection coating, one screen, with stand, black

Panel
Type: Monochrome (IPS)
Backlight: LED
Size: 54.1 cm / 21.3"
Native Resolution: 2048 x 2560 (4:5 aspect ratio)
Viewable Image Size (H x V): 337.9 x 422.4 mm
Pixel Pitch: 0.165 x 0.165 mm
Grayscale Tones: 10-bit (DisplayPort): 1,024 from a palette of 16,369 (14-bit) tones
8-bit: 256 from a palette of 16,369 (14-bit) tones
Viewing Angles (H / V, typical): 178° / 178°
Brightness (typical): 2500 cd/m2
Recommended Brightness for Calibration: 1000 cd/m2, 600 cd/m2
Contrast Ratio (typical): 1700:1
Response Time (typical): 12 ms (black-white-black)

Video Signals
Input Terminals: DisplayPort x 2, DVI-D (dual link)
Output Terminals: DisplayPort (daisy chain)
Digital Scanning Frequency (H / V): 31 - 135 kHz / 23 - 61 Hz

USB
Upstream: USB 2.0: Type-B x 2
Downstream: USB 2.0: Type-A x 2

Power
Power Requirements: AC 100 - 240 V: 50 / 60 Hz
Typical Power Consumption: 28 W
Maximum Power Consumption: 79 W
Power Save Mode: 1 W or less
Sensor: Backlight Sensor, Integrated Front Sensor, Presence Sensor, Ambient Light Sensor

Features & Functions
Brightness Stabilization: Yes
Digital Uniformity Equalizer: Yes
Work-and-Flow: Switch-and-Go, Point-and-Focus
Preset Modes: CAL Switch (DICOM, CAL1, CAL2, Text)
OSD Languages: English, German, French, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese

Physical Specifications
Net Weight:
GX560-MD, GX560-AR-MD: 17.1 kg
GX560, GX560-AR: 8 kg
Net Weight (Without Stand): 5.2 kg
Hole Spacing (VESA Standard): 100 x 100 mm

Certifications & Standards (Please contact EIZO for the latest information.):
GX560, GX560-AR: CE (Medical Device), EN60601-1, ANSI/AAMI ES60601-1, CSA C22.2 No. 601-1, IEC60601-1, VCCI-B, FCC-B, CAN ICES-3 (B), RCM, RoHS, China RoHS, WEEE, CCC, EAC

FDA
510(k) Clearance for Breast Tomosynthesis, Mammography, and General Radiography

Dedicated Software
Monitor Quality Control Software RadiCS Supported

Supplied Accessories (May vary by country. Please contact EIZO for details.)
Signal Cables
GX560-MD, GX560-AR-MD: DisplayPort (3 m) x 4, DisplayPort (1 m)
GX560, GX560-AR: DisplayPort (3 m) x 2
Others
GX560-MD, GX560-AR-MD: AC power cord (3 m) x 2, USB cable (3 m) x 4, Utility Disk (RadiCS LE, PDF installation manual), instructions for use
GX560, GX560-AR: AC power cord (3 m), USB cable (3 m) x 2, Utility Disk (RadiCS LE, PDF installation manual), instructions for use